TM 5-3895-373-20
13.6.
REPLACE HYDRAULIC RETURN FILTER ASSEMBLY - Continued.
A.
REMOVE - Continued.
Cleaning solvent, P-D-680, is TOXIC
and flammable. Wear protective
goggles and gloves. Use only in a
well ventilated area. Avoid contact
with skin, eyes, and clothes, and do
not breathe vapors. Keep away from
heat or flame. Never smoke when
using solvent; the flashpoint for Type
III cleaning solvent is 200°F (93,3°C).
Failure to do so may result in injury
or death to personnel. If personnel
become dizzy while using cleaning
solvent, immediately get fresh air and
medical help. If solvent contacts skin
or clothes, flush with cold water. If
solvent contacts eyes, flush eyes
with water and get immediate medical
attention.
c.
Clean hydraulic hose ends and fittings with
cleaning solvent and lint-free cloth.
d.
Place machinery wiping towels under hydraulic
return filter assembly (3).
e.
Place drip pan under hydraulic return filter
assembly (3).
Hydraulic oil can be moderately
flammable and can be an irritant to
the
skin,
eyes,
and
respiratory
system. Avoid prolonged exposure.
Eye protection and rubber gloves
must be worn when working with
hydraulic oil.
f.
With the help of another person, tag and
unscrew hydraulic hoses (4 and 5) with a
combination wrench. Drain hydraulic oil from
hydraulic return filter assembly into drip pan.
Dispose of hydraulic oil and contaminated
machinery wiping towels in accordance with local
procedures.
g.
Plug hydraulic hoses to prevent contamination.
GO TO NEXT PAGE
13-36