TM 5-3895-373-2013.6.REPLACE HYDRAULIC RETURN FILTER ASSEMBLY - Continued.B.INSTALL - Continued.Do not use pressure gauge suppliedwith new replacement hydraulicreturn filter assembly. Reusepressure gauge removed from oldfilter assembly, or use correctpressure gauge obtained from supplysystem.e.Use cleaning cloth to wipe residue from threadsof elbow (7) and pressure gauge (6).Pipe sealant can cause eye damageor skin irritation. Wash after skincontact. Wear safety goggles/glasseswhen using. Avoid contact with eyesor skin. If sealant contacts eyes,flush eyes with water and getimmediate medical attention.Ensure pipe plug is installed on theIN port side of hydraulic return filterhead opposite the pressure gaugeport.f.Apply pipe sealant to male threads of elbow (7).Install elbow into filter head near the IN port.Elbow should point out at an angle toward theleft access cover opening.g.Apply pipe sealant to male threads of pressuregauge (6). Thread pressure gauge into elbow(7). Ensure the pipe plug is installed oppositethe pressure gauge.GO TO NEXT PAGE13-38