TM 5-3895-373-20
13.6.
REPLACE HYDRAULIC RETURN FILTER ASSEMBLY - Continued.
B.
INSTALL - Continued.
Do not use pressure gauge supplied
with
new
replacement
hydraulic
return
filter
assembly.
Reuse
pressure gauge removed from old
filter
assembly,
or
use
correct
pressure gauge obtained from supply
system.
e.
Use cleaning cloth to wipe residue from threads
of elbow (7) and pressure gauge (6).
Pipe sealant can cause eye damage
or skin irritation. Wash after skin
contact. Wear safety goggles/glasses
when using. Avoid contact with eyes
or skin. If sealant contacts eyes,
flush
eyes
with
water
and
get
immediate medical attention.
Ensure pipe plug is installed on the
IN port side of hydraulic return filter
head opposite the pressure gauge
port.
f.
Apply pipe sealant to male threads of elbow (7).
Install elbow into filter head near the IN port.
Elbow should point out at an angle toward the
left access cover opening.
g.
Apply pipe sealant to male threads of pressure
gauge (6). Thread pressure gauge into elbow
(7). Ensure the pipe plug is installed opposite
the pressure gauge.
GO TO NEXT PAGE
13-38
![](//www.tpub.com/assessment.jpg)