TM 5-3895-373-20B.INSTALL - Continued.i.Use an oil filter removal tool to remove hydraulicreturn filter element (10).Hydraulic oil can be moderatelyflammable and can be an irritant tothe skin, eyes, and respiratorysystem. Avoid prolonged exposure.Eye protection and rubber glovesmust be worn when working withhydraulic oil.j.Coat gasket (11) with clean hydraulic oil. Placegasket on hydraulic return filter head (12).k.Fill hydraulic return filter element (10) withhydraulic oil. Allow time for filter element toabsorb hydraulic oil. Repeat until filter elementis full.I.Install hydraulic return filter element (10).Tighten hand tight plus 3/4 of a turn with oil filterremoval tool.NOTEFOLLOW-ON-TASKS:Add hydraulic oil per TM 5-3895-373-10.Install left access cover per TM 5-3895-373-10.Close left access door per TM 5-3895-373-10.END OF TASK13-41