TM 5-3895-373-20
13.5.
REPLACE HIGH SPEED SHIFT AND BRAKE VALVE SOLENOID ASSEMBLIES AND STACK VALVE
ELECTRICAL COILS - Continued.
B.
INSTALL - Continued.
e.
Apply electrical insulating compound to male end
of electrical connector (8) and install into female
harness connector.
Thread locking compound solvent
can cause eye damage. Wear safety
goggles/glasses when using. Avoid
contact with eyes. If solvent contacts
eyes, flush eyes with water and get
immediate medical attention.
f.
Clean threads of hex head cap screw (5) with
thread locking compound solvent.
g.
Install lockwasher (6) and ground wire (7) on hex
head cap screw (5).
Thread locking compound can cause
eye
damage.
Wear
safety
goggles/glasses when using. Avoid
contact with eyes. If compound
contacts eyes, flush eyes with water
and get immediate medical attention.
h.
Apply thread locking compound to threads of hex
head cap screw (5).
i.
Install hex head cap screw (5). Tighten hex
head cap screw to 37 Ib-ft (50 Nm).
Electrical insulating varnish fumes
can be harmful if inhaled. Use only in
a
well
ventilated
area.
Avoid
prolonged exposure to fumes. If
personnel become dizzy or drowsy
during use, get immediate medical
attention.
j.
Apply electrical insulating varnish to ground wire
(6) ring terminal.
GO TO NEXT PAGE
13-32