TM 5-3895-373-2013.5.REPLACE HIGH SPEED SHIFT AND BRAKE VALVE SOLENOID ASSEMBLIES AND STACK VALVEELECTRICAL COILS - Continued.B.INSTALL - Continued.e.Apply electrical insulating compound to male endof electrical connector (8) and install into femaleharness connector.Thread locking compound solventcan cause eye damage. Wear safetygoggles/glasses when using. Avoidcontact with eyes. If solvent contactseyes, flush eyes with water and getimmediate medical attention.f.Clean threads of hex head cap screw (5) withthread locking compound solvent.g.Install lockwasher (6) and ground wire (7) on hexhead cap screw (5).Thread locking compound can causeeye damage. Wear safetygoggles/glasses when using. Avoidcontact with eyes. If compoundcontacts eyes, flush eyes with waterand get immediate medical attention.h.Apply thread locking compound to threads of hexhead cap screw (5).i.Install hex head cap screw (5). Tighten hexhead cap screw to 37 Ib-ft (50 N•m).Electrical insulating varnish fumescan be harmful if inhaled. Use only ina well ventilated area. Avoidprolonged exposure to fumes. Ifpersonnel become dizzy or drowsyduring use, get immediate medicalattention.j.Apply electrical insulating varnish to ground wire(6) ring terminal.GO TO NEXT PAGE13-32