TM 5-3895-373-20B.INSTALL - Continued.2.INSTALL HYDRAULIC RETURN FILTERASSEMBLY.Hydraulic fitting sealant can causeeye damage or skin irritation. Washafter skin contact. Wear safetygoggles/glasses when using. Avoidcontact with eyes or skin. If sealantcontacts eyes, flush eyes with waterand get immediate medical attention.a.Apply hydraulic fitting sealant to threads ofelbows (9).Orient the hydraulic return filterassembly so that the IN port will befacing toward the outside of thepaving machine and the pressuregauge is facing toward the operatorplatform. Filter will not operateproperly and system damage couldoccur if the filter is installedbackward.b.Orient hydraulic return filter assembly (3) so theIN port is facing the outside of the pavingmachine.c.With the help of another person, position thehydraulic return filter assembly into the accesscover opening and install hydraulic hoses (4 and5). Tighten hoses with a combination wrench.GO TO NEXT PAGE13-39