TM 5-3895-373-20
B.
INSTALL - Continued.
2.
INSTALL HYDRAULIC RETURN FILTER
ASSEMBLY.
Hydraulic fitting sealant can cause
eye damage or skin irritation. Wash
after skin contact. Wear safety
goggles/glasses when using. Avoid
contact with eyes or skin. If sealant
contacts eyes, flush eyes with water
and get immediate medical attention.
a.
Apply hydraulic fitting sealant to threads of
elbows (9).
Orient
the
hydraulic
return
filter
assembly so that the IN port will be
facing toward the outside of the
paving machine and the pressure
gauge is facing toward the operator
platform. Filter will not operate
properly and system damage could
occur
if
the
filter
is
installed
backward.
b.
Orient hydraulic return filter assembly (3) so the
IN port is facing the outside of the paving
machine.
c.
With the help of another person, position the
hydraulic return filter assembly into the access
cover opening and install hydraulic hoses (4 and
5). Tighten hoses with a combination wrench.
GO TO NEXT PAGE
13-39