TM 5-3895-373-20
B.
INSTALL - Continued.
2.
INSTALL BRAKE VALVE SOLENOID
ASSEMBLY.
Cleaning solvent, P-D-680, is TOXIC
and flammable. Wear protective
goggles and gloves. Use only in a
well ventilated area. Avoid contact
with skin, eyes, and clothes, and do
not breathe vapors. Keep away from
heat or flame. Never smoke when
using solvent; the flashpoint for Type
m cleaning solvent is 200°F (93,3°C).
Failure to do so may result in injury
or death to personnel.
If personnel become dizzy while
using cleaning solvent, immediately
get fresh air and medical help. If
solvent contacts skin or clothes,
flush with cold water. If solvent
contacts eyes, flush eyes with water
and get immediate medical attention.
Thread locking compound solvent
can cause eye damage. Wear safety
goggles/glasses when using. Avoid
contact with eyes. If solvent contacts
eyes, flush eyes with water and get
immediate medical attention.
a.
Wipe off solenoid armature (10) with a lint-free
cloth and cleaning solvent. Clean threads of
solenoid armature with thread locking compound
solvent.
b.
Install solenoid assembly (11) onto solenoid
armature (10).
Thread locking compound can cause
eye
damage.
Wear
safety
goggles/glasses when using. Avoid
contact with eyes. If compound
contacts eyes, flush eyes with water
and get immediate medical attention.
c.
Apply thread locking compound to threads of
solenoid armature (10).
d.
Install hex nut (9) onto solenoid armature (10).
Tighten to 14 lb-in (1,6 Nm).
GO TO NEXT PAGE
13-31