TM 5-3895-373-20
B.
INSTALL - Continued.
6.
RECONNECT BATTERIES.
WARNING
When connecting batteries, connect
positive
battery
cable
before
connecting negative battery cable.
Failure to connect batteries in the
proper
sequence
may
lead
to
electrical shock or short circuit and
result in severe personnel injury.
a.
Reconnect positive battery cable (6) and
battery nut (4) to positive terminal of
inboard battery.
b.
Reconnect negative battery cable (5) and
battery nut (4) to negative terminal of
outboard battery.
WARNING
Electrical insulating varnish fumes
can be harmful if inhaled. Use only in
a
well
ventilated
area.
Avoid
prolonged exposure to fumes. If
personnel become dizzy or drowsy
during use, get immediate medical
attention.
c.
Apply
electrical
insulating
varnish
to
terminals and to battery.
d.
Install battery terminal caps (3) to battery
terminals.
e.
Install battery box covers (2) on both
batteries and buckle battery box holddown
straps (1).
NOTE
FOLLOW-ON-TASKS:
Install engine access cover per paragraph 2.22.
Install left access cover per TM 5-3895-373-10.
Close left access door per TM 5-3895-373-10.
Close center top left access door per TM 5-3895-373-10.
Close center top right access door per TM 5-3895-373-10.
Close front top right access door per TM 5-3895-373-10.
Close front top left access door per TM 5-3895-373-10.
Close rear top left access door per TM 5-3895-373-10.
END OF TASK
7-155