TM 5-3895-373-20
B.
INSTALL - Continued.
g.
Reconnect lead wire 161 (27), lead wire 160
(26), and lead wire 167 (25) to voltage
transformer 24 V terminal.
WARNING
Electrical insulating varnish fumes
can be harmful if inhaled. Use only in
a well ventilated area. Avoid
prolonged exposure to fumes. If
personnel become dizzy or drowsy
during use, get immediate medical
attention.
h.
Install lockwasher (24) and hex nut (23) on
voltage transformer 24 V terminal. Apply
electrical insulating varnish to hex nut and
voltage transformer 24 V terminal.
i.
Apply electrical insulating compound to
DCA harness connector (22). Connect
DCA harness connector to positive battery
cable harness.
j.
Do not reconnect positive battery cable (6)
to battery terminal.
4.
INSTALL JUMPER BATTERY CABLES.
a.
Install jumper battery cable (21) to positive
terminal of outboard battery and negative
terminal of inboard battery.
b.
Install battery nuts (16). Apply electrical
insulating varnish to battery terminals and
battery nuts.
c.
Install battery terminal caps (15) to battery
terminals.
d.
Reconnect jumper lead wire (20) terminals
and
lead
wire
166
(19)
to
voltage
transformer 12 V terminal.
e.
Install lockwasher (18) and hex nut (17) on
voltage transformer 12 V terminal. Apply
electrical insulating varnish to hex nut and
voltage transformer 12 V terminal.
GO TO NEXT PAGE
7-153