TM 5-3895-373-207.11.REPLACE/REPAIR VOLTAGE TRANSFORMER - Continued.E. CONNECT.When connecting batteries, connectpositive battery cable beforeconnecting negative battery cable.Failure to connect batteries in theproper sequence may lead toelectrical shock or short circuit andresult in severe personnel injury.1.RECONNECT POSITIVE BATTERY CABLE(6) AND BATTERY NUT (4) TO POSITIVETERMINAL OF INBOARD BATTERY.2.RECONNECT NEGATIVE BATTERY CABLE(5) AND BATTERY NUT (4) TO NEGATIVETERMINAL OF OUTBOARD BATTERY.Electrical insulating varnish fumescan be harmful if inhaled. Use only ina well ventilated area. Avoidprolonged exposure to fumes. Ifpersonnel become dizzy or drowsyduring use, get immediate medicalattention.3.APPLY ELECTRICAL INSULATING VARNISHTO BATTERY TERMINALS.4.INSTALL RUBBER BATTERY TERMINALCAPS (3) ONTO BATTERY TERMINALS.5.INSTALL BATTERY BOX COVERS (2) ANDBUCKLE BATTERY BOX HOLDDOWNSTRAPS (1).NOTEFOLLOW-ON-TASKS:Close rear top left access door per TM 5-3895-373-10.Install left access cover per TM 5-3895-373-10.END OF TASK7-102