TM 5-3895-373-207.11.REPLACE/REPAIR VOLTAGE TRANSFORMER - Continued.C.REMOVE - Continued.2.REMOVE RELAYS.a.Remove hex head cap screws (22), flat washers(23), and ground wire terminals (24). Tag wires.b.Remove start relay (25) and induction heaterrelay (26) from transformer panel (27). Becareful not to damage wiring.3.REMOVE VOLTAGE TRANSFORMER.a.With the help of another person to supporttransformer panel (27), remove hex nuts (28),lockwashers (29), flat washers (30), and sockethead cap screws (31). Discard lockwashers.b.Remove transformer panel (27) from pavingmachine.c.Remove hex nuts (32), lockwashers (33), flatwashers (34), and socket head cap screws (35).Discard lockwashers.d.Remove voltage transformer (36) fromtransformer panel (27).GO TO NEXT PAGE7-98