TM 5-3895-373-20D. INSTALL.1.INSTALL VOLTAGE TRANSFORMER.Thread locking compound solventcan cause eye damage. Wear safetygoggles/glasses when using. Avoidcontact with eyes. If solvent contactseyes, flush eyes with water and getimmediate medical attention.a.Clean threads of socket head cap screws (31and 35) with thread locking compound solvent.Thread locking compound can causeeye damage. Wear safetygoggles/glasses when using. Avoidcontact with eyes. If compoundcontacts eyes, flush eyes with waterand get immediate medical attention.b.Apply thread locking compound (Item 13,Appendix C) to threads of socket head capscrews (35).c.Install voltage transformer (36) onto transformerpanel (27).d.Install socket head cap screws (35), flat washer(34), lockwashers (33), and hex nuts (32).e.Tighten hex nuts (32) to 9 lb-ft (12 N-m).f.Apply thread locking compound (Item 12,Appendix C) to threads of socket head capscrews (31).g.With the help of another person, installtransformer panel (27) into paving machine andsecure with socket head cap screws (31), flatwashers (30), lockwashers (29), and hex nuts(28).h.Using hex head driver socket, tighten sockethead cap screws (31) to 37 lb-ft (50 N•m).GO TO NEXT PAGE7-99