TM 5-3895-373-20
D.
INSTALL.
1.
INSTALL VOLTAGE TRANSFORMER.
Thread locking compound solvent
can cause eye damage. Wear safety
goggles/glasses when using. Avoid
contact with eyes. If solvent contacts
eyes, flush eyes with water and get
immediate medical attention.
a.
Clean threads of socket head cap screws (31
and 35) with thread locking compound solvent.
Thread locking compound can cause
eye
damage.
Wear
safety
goggles/glasses when using. Avoid
contact with eyes. If compound
contacts eyes, flush eyes with water
and get immediate medical attention.
b.
Apply thread locking compound
(Item
13,
Appendix C) to threads of socket head cap
screws (35).
c.
Install voltage transformer (36) onto transformer
panel (27).
d.
Install socket head cap screws (35), flat washer
(34), lockwashers (33), and hex nuts (32).
e.
Tighten hex nuts (32) to 9 lb-ft (12 N-m).
f.
Apply thread locking compound
(Item
12,
Appendix C) to threads of socket head cap
screws (31).
g.
With
the
help
of
another
person,
install
transformer panel (27) into paving machine and
secure with socket head cap screws (31), flat
washers (30), lockwashers (29), and hex nuts
(28).
h.
Using hex head driver socket, tighten socket
head cap screws (31) to 37 lb-ft (50 Nm).
GO TO NEXT PAGE