TM 5-3895-373-20
7.11.
REPLACE/REPAIR VOLTAGE TRANSFORMER - Continued.
D.
INSTALL - Continued.
2.
INSTALL ELECTRICAL CONNECTIONS.
a.
Reconnect wire terminals 103 and 159 (20 and 21)
to voltage transformer 12 V terminal.
Do not overtighten nuts installed on
terminal studs. Overtightening can
cause the stud to turn and cause
internal
damage
to
the
voltage
transformer.
b.
Use a backup wrench and install lockwasher
(19) and hex nut (18) on voltage transformer 12
V terminal. Using crowfoot wrench, tighten hex
nut to 100 lb-in (11 Nm).
c.
Reconnect wire terminal 161 (12), wire terminal
160 (11), and wire terminal 167 (10) to
voltage transformer 24 V terminal.
d.
Install lockwasher (8) and hex nut (7) in voltage
transformer 24 V terminal. Using crowfoot
wrench, tighten hex nut to 100 lb-in (11 N m).
e.
Reconnect wire terminal G200 (9) to voltage
transformer ground terminal.
f.
Install lockwasher (8) and hex nut (7) on voltage
transformer ground terminal. Using crowfoot
wrench, tighten hex nut to 100 lb-in (11 Nm).
Electrical insulating varnish fumes
can be harmful if inhaled. Use only in
a
well
ventilated
area.
Avoid
prolonged exposure to fumes. If
personnel become dizzy or drowsy
during use, get immediate medical
attention.
g.
Coat all terminals and hex nuts with electrical
insulating varnish.
GO TO NEXT PAGE
7-100