TM 5-3895-373-20C. REMOVE.1.REMOVE ELECTRICAL CONNECTIONS.Ensure terminal studs are notloosened during hex nut removal. Ifstuds are loosened, ensure they arehand tightened only. Damage to thevoltage transformer may occur if thestuds are overtightened.NOTEIt may be necessary to hold jam nutswith a backup wrench to allowremoval of hex nuts, and to ensurestuds are not loosened.a.Use a backup wrench and remove hex nuts (7)and lockwashers (8) from voltage transformerground and 24 V terminals. Discardlockwashers.b.Tag and remove wire terminal G200 (9) fromvoltage transformer ground terminal.c.Tag and remove wire terminal 167 (10), wireterminal 160 (11), and wire terminal 161 (12)from voltage transformer 24 V terminal.d.Remove hex nut (18) and lockwasher (19) fromvoltage transformer 12 V terminal. Discardlockwasher.e.Tag and remove wire terminals 103 and 159 (20and 21) from voltage transformer 12 V terminal.GO TO NEXT PAGE7-97