TM 5-3895-373-20B.INSTALL - Continued.2.INSTALL STARTER CABLES AND ENGINEHARNESS WIRES.a.Install wire 333 (16) onto starter groundmounting stud. Install lockwasher (18) and hexnut (17). Tighten hex nut to 42 lb-ft (57 N•m).b.Install wire 166 (15) and wire 332 (14) ontostarter S terminal. Install flat washer (13),lockwasher (12), and hex nut (11) and tightenhex nut.NOTEDo not use lockwasher that comeswith starter and is installed on starterB terminal. Discard lockwasher.c.Install wire 331 (10) onto starter B terminal.Install positive battery cable (9) and slave cable(8). Install and tighten hex nut (7).Electrical insulating varnish fumescan be harmful if inhaled. Use only ina well ventilated area. Avoidprolonged exposure to fumes. Ifpersonnel become dizzy or drowsyduring use, get immediate medicalattention.d.Coat starter B and S terminals with electricalinsulating varnish. Place rubber boot from slavecable over starter B terminal.GO TO NEXT PAGE7-17
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business