TM 5-3895-373-207.5.REPLACE START RELAY - Continued.A.REMOVE - Continued.2.REMOVE RELAY WIRES.a.Remove hex nuts (7) and flat washers (8) fromboth relay switch terminals.b.Tag and remove wires 167 (9 and 10) from relayswitch terminal. Tag and remove wire 166 (11)from opposite relay switch terminal.c.Remove hex nuts (12) and flat washers (13)from both relay coil terminals.d.Tag and remove wire 112 (14) and wires G201(15 and 16) from relay coil terminals.3.REMOVE RELAY FROM TRANSFORMERPANEL.a.Remove hex head cap screws (17) and flatwashers (18). Tag and remove ground wireG201 (15) from relay (19).b.Remove relay (19) from transformer panel.B.INSTALL.1.INSTALL RELAY ON TRANSFORMER PANEL.Thread locking compound solventcan cause eye damage. Wear safetygoggles/glasses when using. Avoidcontact with eyes. If solvent contactseyes, flush with water and getimmediate medical attention.a.Clean hex head cap screws (17) with threadlocking compound solvent.b.Install flat washer (18) and ground wire G201(15) onto hex head cap screw (17).GO TO NEXT PAGE7-20