TM 5-3895-373-20
7.5.
REPLACE START RELAY - Continued.
A.
REMOVE - Continued.
2.
REMOVE RELAY WIRES.
a.
Remove hex nuts (7) and flat washers (8) from
both relay switch terminals.
b.
Tag and remove wires 167 (9 and 10) from relay
switch terminal. Tag and remove wire 166 (11)
from opposite relay switch terminal.
c.
Remove hex nuts (12) and flat washers (13)
from both relay coil terminals.
d.
Tag and remove wire 112 (14) and wires G201
(15 and 16) from relay coil terminals.
3.
REMOVE
RELAY
FROM
TRANSFORMER
PANEL.
a.
Remove hex head cap screws (17) and flat
washers (18). Tag and remove ground wire
G201 (15) from relay (19).
b.
Remove relay (19) from transformer panel.
B.
INSTALL.
1.
INSTALL RELAY ON TRANSFORMER PANEL.
Thread locking compound solvent
can cause eye damage. Wear safety
goggles/glasses when using. Avoid
contact with eyes. If solvent contacts
eyes,
flush
with
water
and
get
immediate medical attention.
a.
Clean hex head cap screws (17) with thread
locking compound solvent.
b.
Install flat washer (18) and ground wire G201
(15) onto hex head cap screw (17).
GO TO NEXT PAGE
7-20