TM 5-3895-373-20
B.
INSTALL - Continued.
WARNING
Thread locking compound can cause
eye
damage./
Wear
safety
goggles/glasses when using. Avoid
contact with eyes. If compound
contacts eyes, flush eyes with water
and get immediate medical attention.
c.
Apply thread locking compound to threads
of hex head cap screws (17).
d.
Install relay (19) with flat washers (18),
ground wire G201 (15), and hex head cap
screws (17). Tighten cap screws to 9 lb-ft
(12 N.m).
2.
CONNECT RELAY WIRES TO RELAY.
a.
Install wires G201 (15 and 16) and wire
112 (14) to relay coil terminals.
b.
Install flat washers (13) and hex nuts (12)
onto both relay coil terminals. Tighten hex
nuts to 18 lb-in (0,9 N.m).
c.
Install wire 166 (11) to relay switch
terminal. Install wires 167 (9 and 10) to
opposite side relay switch terminal.
d.
Install flat washers (8) and hex nuts (7)
onto both relay switch terminals. Tighten
hex nuts to 65 lb-in (7,3 N.m).
WARNING
Electrical insulating varnish fumes
can be harmful if inhaled. Use only in
a
well
ventilated
area.
Avoid
prolonged exposure to fumes. If
personnel become dizzy or drowsy
during use, get immediate medical
attention.
e.
Apply electrical insulating varnish to relay
terminals.
GO TO NEXT PAGE
7-21