TM 5-3895-373-20B.INSTALL - Continued.Thread locking compound can causeeye damage. Wear safetygoggles/glasses when using. Avoidcontact with eyes. If compoundcontacts eyes, flush eyes with waterand get immediate medical attention.2.APPLY THREAD LOCKING COMPOUND TOTHREADS OF SOCKET HEAD CAP SCREW(6).3.INSTALL FIELD RELAY (2) AND SOCKETHEAD CAP SCREW (6). TIGHTEN SOCKETHEAD CAP SCREW.4.INSTALL GROUND WIRE (5), FLATWASHER (4), AND HEX NUT (3).Electrical insulating varnish fumescan be harmful if inhaled. Use only ina well ventilated area. Avoidprolonged exposure to fumes. Ifpersonnel become dizzy or drowsyduring use, get immediate medicalattention.5.APPLY ELECTRICAL INSULATING VARNISHTO HEX NUT (3) AND GROUND WIRE (5).6.APPLY ELECTRICAL INSULATINGCOMPOUND TO HARNESS CONNECTOR (1)AND CONNECT TO FIELD RELAY (2).NOTEFOLLOW-ON-TASK:Close rear top left access door per TM 5-3895-373-10.END OF TASK7-13