TM 5-3895-373-20
B.
INSTALL - Continued.
Thread locking compound can cause
eye
damage.
Wear
safety
goggles/glasses when using. Avoid
contact with eyes. If compound
contacts eyes, flush eyes with water
and get immediate medical attention.
2.
APPLY THREAD LOCKING COMPOUND TO
THREADS OF SOCKET HEAD CAP SCREW
(6).
3.
INSTALL FIELD RELAY (2) AND SOCKET
HEAD CAP SCREW (6). TIGHTEN SOCKET
HEAD CAP SCREW.
4.
INSTALL GROUND WIRE (5), FLAT
WASHER (4), AND HEX NUT (3).
Electrical insulating varnish fumes
can be harmful if inhaled. Use only in
a
well
ventilated
area.
Avoid
prolonged exposure to fumes. If
personnel become dizzy or drowsy
during use, get immediate medical
attention.
5.
APPLY ELECTRICAL INSULATING VARNISH
TO HEX NUT (3) AND GROUND WIRE (5).
6.
APPLY
ELECTRICAL
INSULATING
COMPOUND TO HARNESS CONNECTOR (1)
AND CONNECT TO FIELD RELAY (2).
NOTE
FOLLOW-ON-TASK:
Close rear top left access door per TM 5-3895-373-10.
END OF TASK
7-13