TM 5-3895-373-20
A.
REMOVE - Continued.
e.
Hold spider (45) in bench vise and lightly tap
universal joint yoke (40) to remove bearing
assembly (44).
f.
Turn universal joint yoke (40) over and tap
opposite side to remove remaining bearing
assembly (44).
g.
Discard spider (45) and bearing assemblies (44).
B.
CLEAN.
Cleaning solvent, P-D-680, is TOXIC
and flammable. Wear protective
goggles and gloves. Use only in a
well ventilated area. Avoid contact
with skin, eyes, and clothes, and do
not breathe vapors. Keep away from
heat or flame. Never smoke when
using solvent; the flashpoint for Type
III cleaning solvent is 200°F (93,3°C).
Failure to do so may result in injury
or death to personnel.
If personnel become dizzy when
using cleaning solvent, immediately
get fresh air and medical help. If
solvent contacts skin or clothes,
flush with cold water. If solvent
contacts eyes, flush eyes with water
and get immediate medical attention.
1.
CLEAN
THICKNESS
CONTROL
COMPONENTS.
a.
Clean all components with cleaning solvent. Use
a wire scratch brush to remove hardened
deposits.
b.
Wipe cleaned components dry with a cleaning
cloth.
GO TO NEXT PAGE
15-25