BATTERY-CHARGING ALTERNATOR AND BATTERY-CHARGING ALTERNATOR PULLEY REMOVAL AND INSTALLATION
Figure 2. Battery-Charging Alternator -- Removal.

Field Maintenance Manual For Bituminous Material Paving Machine - 2 Page Navigation
  752    753    754    755    756  757  758    759    760    761    762  
img
.
TM 5-3895-385-23-2
0350
BATTERY-CHARGING ALTERNATOR REMOVAL AND INSTALLATION
Battery-Charging Alternator Removal
Figure 1. Battery-Charging Alternator Electrical Connections.
CAUTION
Tag and label all electrical wires and connectors prior to removal. Electrical wires must be
installed correctly for proper operation. Failure to comply may cause damage to equipment.
1. Disconnect electrical connector (Figure 1, Item 5) from battery-charging alternator (Figure 1, Item 3).
2. Remove bolt (Figure 1, Item 10), lock washer (Figure 1, Item 11), and ground wire (Figure 1, Item 1) from
ground weldment (Figure 1, Item 2). Discard lock washer.
3. Remove nut (Figure 1, Item 7), lock washer (Figure 1, Item 8), power wire (Figure 1, Item 9), and spacer
(Figure 1, Item 6) from stud (Figure 1, Item 4). Discard lock washer.
0350-2