FUEL PUMP ACTUATOR REMOVAL AND INSTALLATION
Fuel Pump Actuator Installation

Field Maintenance Manual For Bituminous Material Paving Machine - 2 Page Navigation
  637    638    639    640    641  642  643    644    645    646    647  
img
.
TM 5-3895-385-23-2
0330
FUEL PUMP ACTUATOR REMOVAL AND INSTALLATION
Fuel Pump Actuator Removal
Figure 1. Fuel Pump Actuator -- Removal/Installation.
1. Tag and disconnect wiring harness W25 C9 (Figure 1, Item 7).
NOTE
Capture all spilled fuel In Accordance With (IAW) local Standard Operating Procedure (SOP).
2. Place wiping rag under fuel pump actuator (Figure 1, Item 5) to capture spilled fuel.
3. Disconnect fuel filter inlet line (Figure 1, Item 2) from fuel pump (Figure 1, Item 1).
4. Remove three mounting screws (Figure 1, Item 6) and fuel pump actuator (Figure 1, Item 5) from fuel pump
(Figure 1, Item 1).
5. Remove two O-rings (Figure 1, Items 3 and 4) from fuel pump actuator (Figure 1, Item 5). Discard O-rings.
0330-2