• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Crankcase Breather and Hose Installation
Figure 1. Fuel Metering Pump -- Removal/Installation.

Field Maintenance Manual For Bituminous Material Paving Machine - 2 Page Navigation
  632    633    634    635    636  637  638    639    640    641    642  
img
. . . . .
TM 5-3895-385-23-2
0329
FIELD MAINTENANCE
BITUMINOUS MATERIAL PAVING MACHINE (BMPM)
FUEL METERING PUMP REMOVAL AND INSTALLATION
INITIAL SETUP:
Tools and Special Tools
Personnel Required
General Mechanics Tool Kit (GMTK) (WP 0440, Vol
91L
3, Item 64)
Equipment Conditions
3/4 inch 3/8 drive crowfoot (WP 0440, Vol 3, Item
BATTERY DISCONNECT switch OFF (TM 5-3895-
74)
385-10)
Cap and plug set (WP 0440, Vol 3, Item 11)
Engine cool
Torque wrench (WP 0440, Vol 3, Item 80)
Engine removed (WP 0323)
Torque wrench (WP 0440, Vol 3, Item 83)
Spin-on fuel filter head assembly removed (WP
0339)
Materials/Parts
Estimated Time to Complete Task
Pipe thread sealant (WP 0439, Vol 3, Item 95)
81 hr
Wiping rag (4) (WP 0439, Vol 3, Item 89)
FUEL METERING PUMP REMOVAL AND INSTALLATION
WARNING
Fuel is combustible and toxic to eyes, skin, and respiratory tract. Skin and eye protection are
required when working in contact with fuel. Avoid repeated or prolonged contact. Provide
adequate ventilation. Operators are to wash exposed skin and change soaked clothing
promptly if exposed to fuel. Failure to comply may cause injury or death to personnel.
Fuels used in the BMPM are combustible. Do not smoke or use open flame when performing
maintenance. Fire and possible explosion may result. Failure to comply may cause injury or
death to personnel and damage to equipment.