• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
RIGHT AUGER FAILS TO TURN
Table 1. Right Auger Fail To Turn Troubleshooting Procedures -- Continued

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  597    598    599    600    601  602  603    604    605    606    607  
img
. . . . . . . . . . . . . .
TM 5-3895-385-23-1
0144
Table 1. Right Auger Fail To Turn Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. If no fault is found, proceed to
next test.
5. Check faults screen for RIGHT
1. If fault is found, proceed to WP
AUGER FORWARD EDC fault.
0147.
2. If no fault is found, proceed to
next test.
6. Check faults screen for RIGHT
1. If fault is found, proceed to WP
AUGER BYPASS fault.
0175.
2. If no fault is found, proceed to
next test.
7. Check fault screen for RIGHT
1. If fault is found, proceed to WP
CONSOLE BEACON KEYPAD
0188.
fault.
2. If no fault is found, proceed to
next test.
8. Check fault screen for LEFT
1. If fault is found, proceed to WP
CONSOLE BEACON KEYPAD
0183.
fault.
2. If no fault is found, proceed to
next test.
9. Check fault screen for RIGHT
1. If fault is found, proceed to WP
CONSOLE LIGHTS KEYPAD
0190.
fault.
2. If no fault is found, proceed to
next test.
10.Check fault screen for LEFT
1. If fault is found, proceed to WP
CONSOLE LIGHTS KEYPAD
0185.
fault.
2. If no fault is found, proceed to
next test.
11.Check fault screen for RIGHT
1. If fault is found, proceed to WP
SCREED AUG/CONV KEYPAD
0191.
fault.
2. If no fault is found, proceed to
next test.
0144-2


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.