Table 1. Left Screed Horn Keypad Fault Troubleshooting Procedures -- Continued
Table 1. Right Console Beacon Keypad Fault Troubleshooting Procedures -- Continued

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  841    842    843    844    845  846  847    848    849    850    851  
img
. . . . . . . . . . . .
TM 5-3895-385-23-1
0188
FIELD MAINTENANCE
BITUMINOUS MATERIAL PAVING MACHINE (BMPM)
RIGHT CONSOLE BEACON KEYPAD FAULT
INITIAL SETUP:
Test Equipment
References -- Continued
Multimeter (WP 0440, Vol 3, Item 37)
WP 0373, Vol 2
Personnel Required
WP 0375, Vol 2
91L
WP 0386, Vol 2
Assistant
WP 0399, Vol 2
References
WP 0443, Vol 3
WP 0180
WP 0444, Vol 3
WP 0181
WP 0448, Vol 3
WP 0182
WP 0451, Vol 3
WP 0213
Equipment Conditions
WP 0266, Vol 2
Engine off (TM 5-3895-385-10)
WP 0277, Vol 2
Hydraulic oil cool (TM 5-3895-385-10)
TROUBLESHOOTING PROCEDURES
Table 1. Right Console Beacon Keypad Fault Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. System fault indicated on fault
1. Turn keyless engine switch to
screen.
the AUX position (TM 5-3895-
385-10), but do not start engine.
2. Check fault screen for SCREED
1. If fault is found, proceed to WP
CONTROLLER OFFLINE fault.
0181.
2. If no fault is found, proceed to
next test.
3. Check fault screen for OUTPUT
1. If fault is found, proceed to WP
MODULE OFFLINE fault.
0182.
2. If no fault is found, proceed to
next test.
4. Check fault screen for PROPEL
1. If fault is found, proceed to WP
CONTROLLER OFFLINE fault.
0180.