Table 1. Right Track Forward EDC Fault Troubleshooting Procedures -- Continued
RIGHT AUGER REVERSE EDC FAULT

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  602    603    604    605    606  607  608    609    610    611    612  
img
TM 5-3895-385-23-1
0145
Table 1. Right Track Forward EDC Fault Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. Measure for continuity (WP
1. If continuity is present, proceed
0443, Vol 3) between known
to next malfunction.
good ground and main wiring
harness W1 J18 Pin B (WP
0451, Vol 3, Figure 10).
2. If no continuity is present,
replace main wiring harness
(WP 0373, Vol 2).
5. Main wiring harness has a short
Measure for continuity (WP 0443,
1. If continuity is present, replace
circuit.
Vol 3) between main wiring harness
main wiring harness (WP 0373,
W1 J2 Pin 38 and all other pins on
Vol 2).
the main wiring harness W1 J2 (WP
0451, Vol 3, Figure 2).
2. If no continuity is present,
replace propel controller module
ECM (WP 0399, Vol 2).
END OF WORK PACKAGE