TM 5-3895-385-23-1
FIELD MAINTENANCE
BITUMINOUS MATERIAL PAVING MACHINE (BMPM)
LEFT CONSOLE BEACON KEYPAD FAULT
INITIAL SETUP:
Test Equipment
References -- Continued
WP 0373, Vol 2
Personnel Required
WP 0374, Vol 2
91L
WP 0386, Vol 2
Assistant
WP 0399, Vol 2
References
WP 0443, Vol 3
WP 0444, Vol 3
WP 0447, Vol 3
WP 0451, Vol 3
Equipment Conditions
WP 0266, Vol 2
Engine off (TM 5-3895-385-10)
WP 0277, Vol 2
Hydraulic oil cool (TM 5-3895-385-10)
TROUBLESHOOTING PROCEDURES
Table 1 Left Console Beacon Keypad Fault Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. System fault indicated on fault
1. Turn keyless engine switch to
screen.
the AUX position (TM 5-3895-
385-10), but do not start engine.
2. Check fault screen for SCREED
1. If fault is found, proceed to WP
CONTROLLER OFFLINE fault.
2. If no fault is found, proceed to
next test.
3. Check fault screen for OUTPUT
1. If fault is found, proceed to WP
MODULE OFFLINE fault.
2. If no fault is found, proceed to
next test.
4. Check fault screen for PROPEL
1. If fault is found, proceed to WP
CONTROLLER OFFLINE fault.