TM 5-3895-385-23-1
0144
Table 1. Right Auger Fail To Turn Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3. Check hydraulic pressure at
1. If hydraulic pressure reads a
hydraulic pressure forward test
minimum of 500 pounds per
port on the variable auger pump
square inch (psi) (3,447
(WP 0319, Vol 2) while
kiloPascals (kPa)), turn keyless
attempting to turn on the right
engine switch to the OFF
auger forward full speed in
position (TM 5-3895-385-10),
manual mode (TM 5-3895-385-
and proceed to next test.
10).
2. If pressure reads below 500 psi
(3,447 kPa), turn keyless engine
switch to the OFF position (TM
5-3895-385-10), and proceed to
variable auger pump
4. Attach hydraulic pressure tester
(WP 0442, Vol 3) to hydraulic
pressure reverse test port on the
variable auger pump (WP 0449,
Vol 3, Figure 1).
5. Start BMPM engine (TM 5-3895-
385-10).
6. Check hydraulic pressure at
1. If hydraulic pressure reads a
hydraulic pressure test port on
minimum of 300 psi (2,068 kPa),
the variable auger pump (WP
turn keyless engine switch to
0319, Vol 2) while attempting to
the OFF position (TM 5-3895-
turn on the right auger reverse
385-10), and replace right auger
full speed in manual mode (TM
drive motor and manifold (WP
5-3895-385-10).
0406, Vol 2).
2. If pressure reads below 300 psi
(2,068 kPa), turn keyless engine
switch to the OFF position (TM
5-3895-385-10), and proceed to
variable auger pump
END OF WORK PACKAGE
0144-4