Table 1. Left Auger Bypass Fault Troubleshooting Procedures -- Continued
Table 1. Right Auger Bypass Fault Troubleshooting Procedures -- Continued

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  695    696    697    698    699  700  701    702    703    704    705  
img
. . . . .
TM 5-3895-385-23-1
0175
FIELD MAINTENANCE
BITUMINOUS MATERIAL PAVING MACHINE (BMPM)
RIGHT AUGER BYPASS FAULT
INITIAL SETUP:
Test Equipment
References -- Continued
Multimeter (WP 0440, Vol 3, Item 37)
WP 0373, Vol 2
Personnel Required
WP 0377, Vol 2
91L
WP 0399, Vol 2
Assistant
WP 0443, Vol 3
References
WP 0451, Vol 3
WP 0180
Equipment Conditions
WP 0316, Vol 2
Engine off (TM 5-3895-385-10)
Hydraulic oil cool (TM 5-3895-385-10)
TROUBLESHOOTING PROCEDURES
Table 1. Right Auger Bypass Fault Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. System fault indicated on fault
1. Turn keyless engine switch to
screen.
the AUX position (TM 5-3895-
385-10), but do not start engine.
2. Check fault screen for PROPEL
1. If fault is found, proceed to WP
CONTROLLER OFFLINE fault.
0180.
2. If no fault is found, proceed to
next malfunction.
2. Hydraulic solenoid malfunction.
1. Disconnect bulkhead wiring
harness W11 J5 from right auger
bypass hydraulic solenoid (WP
0451, Vol 3, Figure 29).
2. Turn auger conveyor to full
speed in manual mode (TM 5-
3895-385-10).
3. Attempt to turn on right auger
bypass (TM 5-3895-385-10).
0175-1