TM 5-3895-385-23-1
FIELD MAINTENANCE
BITUMINOUS MATERIAL PAVING MACHINE (BMPM)
RIGHT TRACK FORWARD EDC FAULT
INITIAL SETUP:
Test Equipment
References -- Continued
WP 0373, Vol 2
Personnel Required
WP 0399, Vol 2
91L
WP 0443, Vol 3
Assistant
WP 0451, Vol 3
References
Equipment Conditions
Engine off (TM 5-3895-385-10)
WP 0320, Vol 2
TROUBLESHOOTING PROCEDURES
Table 1. Right Track Forward EDC Fault Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Propel Controller Offline fault
1. Turn keyless engine switch to
indicated on fault screen.
the AUX position (TM 5-3895-
385-10), but do not start engine.
2. Check fault screen for PROPEL
1. If fault is found, turn keyless
CONTROLLER OFFLINE fault.
engine switch to the OFF
position (TM 5-3895-385-10),
2. If no fault is found, turn keyless
engine switch to the OFF
position (TM 5-3895-385-10),
and proceed to next malfunction.
2. Propulsion pump malfunction.
1. Locate W1 J18 at propulsion
pump (WP 0373, Vol 2).
.
2. Turn keyless engine switch to
the AUX position (TM 5-3895-
385-10), but do not start engine.