TM 5-3895-373-34
2.65
REPLACE/REPAIR CONVEYOR ROLLER AND BEARING UNITS - Continued.
B.
CLEAN - Continued.
2.
CLEAN
BEARING
SUPPORT
PLATE
MOUNTING SURFACES.
WARNING
Cleaning solvent, P-D-680, is TOXIC
and flammable. Wear protective
goggles and gloves. Use only in a
well ventilated area. Avoid contact
with skin, eyes, and clothes, and do
not breathe vapors. Keep away from
heat or flame. Never smoke when
using solvent; the flashpoint for Type
m cleaning solvent is 200°F (93,3°C).
Failure to do so may result in injury
or death to personnel.
If personnel become dizzy while
using cleaning solvent, immediately
get fresh air and medical help. If
solvent contacts skin or clothes,
flush with cold water. If solvent
contacts eyes, flush eyes with water
and get immediate medical attention.
a.
Clean paving machine main frame at bearing
support plate mounting surfaces using cleaning
cloths soaked in cleaning solvent. If necessary,
use a wire scratch brush to remove built up dirt
and residue. Give special attention to bolt holes.
Wipe away all residue.
b.
Clean outer edges of tension bolt through-holes
on bearing support plate with cleaning solvent.
Wipe away all residue with a cleaning cloth.
c.
Dry all parts with a cleaning cloth.
GO TO NEXT PAGE
2-888