TM 5-3895-373-34
B.
CLEAN.
1.
CLEAN ALL METAL PARTS.
WARNING
Cleaning solvent, P-D-680, is TOXIC and
flammable. Wear protective goggles and
gloves. Use only in a well ventilated area.
Avoid contact with skin, eyes, and clothes,
and do not breathe vapors. Keep away from
heat or flame. Never smoke when using
solvent; the flashpoint for Type III cleaning
solvent is 200°F (93,3°C). Failure to do so
may result in injury or death to personnel.
If personnel become dizzy while using
cleaning solvent, immediately get fresh air
and medical help. If solvent contacts skin or
clothes, flush with cold water. If solvent
contacts eyes, flush eyes with water and get
immediate medical attention.
a.
Rinse and clean all metal parts in cleaning
solvent. Give special attention to bearing
lubrication hole. Wipe away all residue with a
cleaning cloth.
b.
Clean lubrication fitting of old grease.
WARNING
Thread locking compound solvent can cause
eye damage. Wear safety goggles/glasses
when using. Avoid contact with eyes. If
solvent contacts eyes, flush eyes with water
and get immediate medical attention.
c.
Clean all fastener threads using thread locking
compound solvent.
d.
Dry all parts with a cleaning cloth.
GO TO NEXT PAGE
2-887