TM 5-3895-373-34
A.
REMOVE.
1.
REMOVE ENDGATE.
a.
Disconnect feed limit switch connector (1) from
rear wall of tractor.
b.
Using hinged handle and socket from socket
wrench set, remove hex nut (2), lockwasher (3),
and flat washer (4). Do not discard lockwasher
at this time.
c.
Remove self-locking nuts (5), flat washers (6
and 7), and hex head cap screws (8 and 9).
Discard self-locking nuts.
d.
While second person holds endgate (10) upright,
remove hex head cap screws (11) and flat
washers (12) securing endgate support arm (13)
to extension screed (14).
WARNING
Endgate weighs approximately 126
lbs (57 kg). To avoid personal injury,
do not attempt to lift and remove the
endgate. Use a second person to
help remove the endgate. Failure to
do so may result in serious injury.
e.
With help of second person, lift and remove
endgate (10) from extension screed (14).
NOTE
Screed extension cylinder piston rod
hardware (2, 3, and 4) should be
reinstalled to allow extension screed
to
be
repositioned
during
components removal procedures.
f.
Reinstall flat washer (4), lockwasher (3), and hex
nut (2). Using hinged handle and socket from
socket wrench set, tighten hex nut.
GO TO NEXT PAGE
2-893