TM 5-3895-373-34
A.
REMOVE - Continued.
3.
REMOVE RETURN MANIFOLD.
Hydraulic
oil
can
be
moderately
flammable and can be an irritant to
the
skin,
eyes,
and
respiratory
system. Avoid prolonged exposure.
Eye protection and rubber gloves
must be worn when working with
hydraulic oil.
Thoroughly clean hoses and fittings
before disconnecting. Always plug or
cap off fittings to prevent intrusion of
contaminates. Failure to properly
clean and cap off connectors may
result in system contamination or
equipment damage.
NOTE
The return manifold needs to be
removed
if
removing
the
auger/conveyor flow divider or valve
and cylinder flow divider.
a.
Wipe all dirt and dust from fittings with cleaning
cloths.
b.
Place machinery wiping towels below return
manifold.
c.
Tag and disconnect hoses (5 and 6) from
elbows (7 and 8) on return manifold (9). Plug
hoses and cap elbows.
NOTE
It may be necessary to loosen and/or
remove hydraulic tubes at both ends
to
allow
removal
of
the
return
manifold.
d.
Tag and disconnect tubes (10 and 11) from
elbows (12 and 13) on return manifold (9). Plug
tubes and cap elbows.
e. Tag and disconnect tube (14) from straight adapter
(15) on end of return manifold (9). Plug tube and cap
straight adapter.
GO TO NEXT PAGE