TM 5-3895-373-34
2.55.
REPLACE VALVE PANEL CONTROL VALVES AND FLOW DIVIDERS - Continued
A.
REMOVE - Continued.
Hydraulic
oil
can
be
moderately
flammable and can be an irritant to
the
skin,
eyes,
and
respiratory
system. Avoid prolonged exposure.
Eye protection and rubber gloves
must be worn when working with
hydraulic oil.
f.
Tag and disconnect tube (16) from elbow (17)
located on bottom of return manifold (9). Plug
tube and cap elbow.
g.
Tag and disconnect tube (18) from straight
adapter (19) located on bottom of return
manifold (9). Plug tube and cap straight
adapter.
h.
Tag and disconnect tube (20) from elbow (21)
located on bottom of return manifold (9).
GO TO NEXT PAGE