TM 5-3895-373-34
2.55.
REPLACE VALVE PANEL CONTROL VALVES AND FLOW DIVIDERS - Continued
A.
REMOVE - Continued.
2.
REMOVE DCA HOUSING.
NOTE
The DCA housing only needs to be
removed
if
removing
the
right
auger/conveyor control valve and the
right auger/conveyor speed control
valve.
a.
Remove lock screws (1) and self-locking nuts
(2) from housing bracket (3). Discard lock
screws and self- locking nuts.
b.
Remove DCA housing (4) and housing bracket
(3) from engine cowling. Do not disconnect
wires from DCA housing. Set DCA housing on
top of engine cowling.
GO TO NEXT PAGE