TM 5-3895-373-34
A.
DISASSEMBLE - Continued.
3.
REMOVE END PLATES, CASES, AND DOWEL
PINS FROM FLOW DIVIDER.
a.
Remove hex head cap screws (18) and hex nuts
(19).
NOTE
Cases (21) on tow point flow divider
are
thinner
than
cases
on
auger/conveyor
flow
divider
and
valve
and
cylinder
flow
divider.
Procedure for disassembly is the
same for all units.
b.
Pull flow divider apart and separate end plates
(20) from cases (21) and spacer plate (22).
CAUTION
Use caution when removing seals
and preformed packings. Scratched
or dented seal grooves can cause
bypass
leakage.
Do
not
use
excessive force when removing seals
and preformed packings. Use an o-
ring
tool
to
remove
seals
and
preformed packings.
c.
Use an o-ring tool and remove preformed
packings (23) from end plates (20), cases (21),
and spacer plate (22). Discard preformed
packings.
d.
Use a pair of pliers and remove dowel pins (24
and 25) from end plates (20) and cases (21).
e.
Ensure bearings (26) remain with end plates (20)
and spacer plate (22).
GO TO NEXT PAGE
2-665