TM 5-3895-373-34
2.49
REPAIR AUGER/CONVEYOR, VALVE AND CYLINDER, AND TOW POINT FLOW DIVIDERS- Continued.
A.
DISASSEMBLE Continued.
b.
Remove hydraulic fittings from valve and cylinder
flow divider.
(1)
Remove tube reducer (4) from tee (5).
(2)
Remove tee (5) from valve and cylinder
flow divider (6).
(3)
Remove elbow (7) from straight adapter
(8).
(4)
Remove straight adapter (8).
(5)
Remove elbow (9) from valve and cylinder
flow divider (6).
c.
Remove hydraulic fittings from tow point flow
divider.
(1)
Remove elbow (10) from tow point flow
divider (11).
(2)
Remove elbow (12).
(3)
Remove elbows (13 and 14) from tow
point flow divider (11).
2.
REMOVE
MOUNTING
BRACKETS
FROM
FLOW DIVIDER.
a.
Remove hex head cap screws (15) and hex nuts
(16) from flow divider.
b.
Remove mounting brackets (17) from flow
divider.
GO TO NEXT PAGE
2-664