TM 5-3895-373-34
2.46
REPAIR TOW POINT CONTROL VALVE - Continued.
B.
CLEAN - Continued.
Cleaning solvent, P-D-680, is TOXIC
and flammable. Wear protective
goggles and gloves. Use only in a
well ventilated area. Avoid contact
with skin, eyes, and clothes, and do
not breathe vapors. Keep away from
heat or flame. Never smoke when
using solvent; the flashpoint for Type
III cleaning solvent is 200°F (93,3°C).
Failure to do so may result in injury
or death to personnel.
If personnel become dizzy while
using cleaning solvent, immediately
get fresh air and medical help. If
solvent contacts skin or clothes,
flush with cold water. If solvent
contacts eyes, flush eyes with water
and get immediate medical attention.
5.
FLUSH OUTLET MANIFOLD BODY WITH
CLEANING
SOLVENT
TO
REMOVE
ANY
FOREIGN MATERIAL PRESENT. USE A
CULTURE
SWAB
TO
REMOVE
ANY
MATERIAL FROM OUTLET MANIFOLD INNER
BORE.
6.
DRY ALL PARTS WITH A CLEAN, LINT-FREE
CLOTH.
C.
INSPECT.
1.
INSPECT VALVE BODY FOR WEAR AND
DAMAGE.
a.
Visually inspect valve body (15), surface A,
for stripped threads. Inspect seal grooves
B for scratches or dents. Use a strong light
and inspect inner bore C for foreign
material, scoring, or excessive wear.
b.
Replace valve body (15) and spool if
stripped threads, damaged seal grooves,
scoring, or excessive wear are detected.
GO TO NEXT PAGE
2-636