TM 5-3895-373-34
2.43
REPLACE/REPAIR AUXILIARY VIBRATION PUMP - Continued
E.
ASSEMBLE - Continued.
Cleaning solvent, P-D-680, is TOXIC
and flammable. Wear protective
goggles and gloves. Use only in a
well ventilated area. Avoid contact
with skin, eyes, and clothes, and do
not breathe vapors. Keep away from
heat or flame. Never smoke when
using solvent; the flashpoint for Type
III cleaning solvent is 200°F (93, 30C).
Failure to do so may result in injury
or death to personnel.
If personnel become dizzy while
using cleaning solvent, immediately
get fresh air and medical help. If
solvent contacts skin or clothes,
flush with cold water. If solvent
contacts eyes, flush eyes with water
and get immediate medical attention.
i.
Using lint-free cloth dampened with cleaning
solvent, carefully wipe excess petrolatum from
faces of rear cover (18), front flange (20), and
end faces of pump housing (17). Do not
dislodge installed seals and packings.
j.
Dry clean surfaces with clean, dry, lint-free
cloths. Make sure all sealing faces are
completely clean and dry.
k.
Apply light coating of petrolatum to exposed
shaft surfaces of drive gear (30). Petrolatum will
prevent cutting of seal surfaces on spline during
installation of front flange (20).
I.
Install guide pins (26) in guide pin holes of pump
housing (17).
GO TO NEXT PAGE
2-598