TM 5-3895-373-34
F.
INSTALL - Continued.
2.
INSTALL
VIBRATION
RELIEF
VALVE
AND
ADAPTERS.
a.
Remove protective caps from auxiliary vibration
pump (9).
b.
Lubricate preformed packings (5 and 8) with
petrolatum.
Be careful not to damage preformed
packings when sliding over threads.
Sharp edges of threads can cut or
damage preformed packings. Damaged
preformed packings will cause leakage
and affect performance.
c.
Install preformed packing (5) in packing groove
of elbow (4). Using combination wrench, screw
elbow into mating port until preformed packing
meets seat.
d.
Aim elbow (4) at a 45° angle toward right rear
side of paving machine and tighten lock nut.
e. Install preformed packing (8) in packing groove
of elbow (7). Screw elbow into mating port until
preformed packing meets seat. Aim elbow
toward rear of paving machine and tighten lock
nut.
Hydraulic fitting sealant can cause eye
damage or skin irritation. Wash after
skin
contact.
Wear
safety
goggles/glasses when using. Avoid
contact with eyes or skin. If sealant
contacts eyes, flush eyes with water and
get immediate medical attention.
f. Apply hydraulic fitting sealant to threads of
installed elbow (7). Install and tighten vibration
relief valve straight adapter (6), while holding
relief valve upright with straight adapter facing
right
side
of
paving
machine.
GO TO NEXT PAGE
2-601