TM 5-3895-373-34
2.43
REPLACE/REPAIR AUXILIARY VIBRATION PUMP - Continued.
F.
INSTALL - Continued.
3.
INSTALL HYDRAULIC HOSES.
Hydraulic fitting sealant can cause eye
damage or skin irritation. Wash after
skin
contact.
Wear
safety
goggles/glasses when using. Avoid
contact with eyes or skin. If sealant
contacts eyes, flush eyes with water and
get immediate medical attention.
a.
Apply hydraulic fitting sealant to threads of
installed elbow (4) and adapters on vibration
relief valve.
b.
Using combination wrench, install and tighten
hoses (3, 2, and 1).
NOTE
FOLLOW-ON-TASKS: Install left auxiliary pump per paragraph 2.42.
Prime hydraulic pump per paragraph 2.54.
Install right access cover per TM 5-3895-373-10.
Close right access door per TM 5-3895-373-10.
Close front top right access door per TM 5-3895-373-10.
END OF TASK
2-602