TM 5-3895-373-34
E.
ASSEMBLE - Continued.
9.
INSTALL HYDRAULIC ASSEMBLY HOUSING
ONTO MECHANICAL DRIVE HOUSING.
Hydraulic
oil
can
be
moderately
flammable and can be an irritant to
the
skin,
eyes,
and
respiratory
system. Avoid prolonged exposure.
Eye protection and rubber gloves
must be worn when working with
hydraulic oil.
a.
Lubricate
o-ring
(25)
and
preformed
packing (26) with clean hydraulic oil.
b.
Install o-ring (25) and preformed packing
(26) on hydraulic assembly housing (24).
c.
Thread hydraulic assembly housing onto
adjustment
bolt
(21)
while
turning
adjustment bolt counterclockwise.
Thread locking compound can cause
eye
damage.
Wear
safety
goggles/glasses when using. Avoid
contact with eyes. If compound
contacts eyes, flush eyes with water
and get immediate medical attention.
d.
Apply thread locking compound to socket
head cap screws (23).
e.
Install socket head cap screws (23) through
hydraulic assembly housing (24) and into
propulsion motor (10). Use a hex head
driver socket (Item 89, Appendix D) and
tighten screws to 10 lb-ft (14 Nm).
f.
While holding adjustment bolt (21) with an
allen wrench, install nut (22). Do not
tighten nut.
g.
Set adjustment bolt (21) exposed threads to
measurement recorded in step B.1.a. Hold
adjustment bolt with a wrench and tighten
nut.
GO TO NEXT PAGE
2-465