TM 5-3895-373-34G.INSTALL - Continued.3.CONNECT HYDRAULIC TUBES.Hydraulic fitting sealant can cause eyedamage or skin irritation. Wash after skincontact. Wear safety goggles/glasses whenusing. Avoid contact with eyes or skin. Ifsealant contactseyes, flush eyes with waterand get immediate medical attention.Use a backupwrench when tightening flarefittings on hydraulic tubes to preventtwisting or breaking tube. Failure to do somay result intube damage.a.Applyhydraulic fitting sealant to exposedadapterson propulsion motor (10).b.If right propulsion motor was installed,connecttubes (6 and 7) to mating adapters.c.If left propulsion motor was installed,connecttees (4 and 5).d.Connect tubes (1 through 3).NOTEFOLLOW-ON-TASKS:Remove paving machine from jacks and cribbing perTM 5-3895-373-20.Fill hydraulic reservoir per TM 5-3895-373-10.Adjust/calibrate control handles per TM 5-3895-373-20.END OF TASK2-469