TM 5-3895-373-34
G.
INSTALL - Continued.
3.
CONNECT HYDRAULIC TUBES.
Hydraulic fitting sealant can cause eye
damage or skin irritation. Wash after skin
contact. Wear safety goggles/glasses when
using. Avoid contact with eyes or skin. If
sealant contacts eyes, flush eyes with water
and get immediate medical attention.
Use a backup wrench when tightening flare
fittings
on
hydraulic
tubes
to
prevent
twisting or breaking tube. Failure to do so
may result in tube damage.
a.
Apply hydraulic fitting sealant to exposed
adapters on propulsion motor (10).
b.
If right propulsion motor was installed,
connect tubes (6 and 7) to mating adapters.
c.
If left propulsion motor was installed,
connect tees (4 and 5).
d.
Connect tubes (1 through 3).
NOTE
FOLLOW-ON-TASKS:
Remove paving machine from jacks and cribbing per
TM 5-3895-373-20.
Fill hydraulic reservoir per TM 5-3895-373-10.
Adjust/calibrate control handles per TM 5-3895-373-20.
END OF TASK
2-469