TM 5-3895-373-34
F.
INSTALL - Continued.
3.
CONNECT
HYDRAULIC
HOSES
AND
ELECTRICAL
CONNECTIONS
O
LEFT
PROPULSION PUMP.
Hydraulic fitting sealant can cause eye damage
or skin irritation. Wash after skin contact. Wear
safety goggles/glasses when using. Avoid
contact with eyes or skin. If sealant contacts
eyes, flush eyes with water and get immediate
medical attention.
a.
Apply hydraulic fitting sealant to threads of
straight adapters (29, 30, and 33).
b.
Connect propulsion motor hoses (16 and 17) to
straight adapters (33) on propulsion pump.
Tighten motor hoses, using combination wrench
(Item 115, Appendix D).
c.
Connect hydraulic charge filter hose (15) to
elbow (27) on propulsion pump. Connect
hydraulic charge filter hose (14) elbow to straight
adapter (29) on propulsion pump. Tighten hose
and elbow.
d.
Connect propulsion pump suction hose (13) to
elbow (25) on propulsion pump. Tighten suction
hose, using combination wrench (Item 116,
Appendix D).
e.
Connect case drain hose (18) to straight adapter
(30) on propulsion pump. Tighten drain hose.
f.
Apply electrical insulating compound to male
terminals of harness electrical connector (12).
g.
Connect pump pilot control valve electrical
connector (11) to harness electrical connector
(12).
4.
IF
INSTALLING
LEFT
PROPULSION
PUMP,
INSTALL AUXILIARY VIBRATION PUMP ONTO
LEFT PROPULSION PUMP PER PARAGRAPH
2.43.
5.
INSTALL AUXILIARY PUMP PER PARAGRAPH
2.42.
6.
PRIME HYDRAULIC SYSTEM PER PARAGRAPH
2.54.
7.
FILL PUMP DRIVER GEARBOX PER LO 5-3895-
373-12.
GO TO NEXT PAGE