TM 5-3895-373-34
2.23.
REPAIR WATER PUMP - Continued
C.
ASSEMBLE - Continued.
4.
INSTALL
IMPELLER
ONTO
ASSEMBLED
SHAFT.
a.
Place bearing body (2) onto hydraulic press
frame.
b.
Select a spacer from universal puller kit that
will pass over the water pump shaft. Place on
top of impeller (3).
c.
Press impeller (3) onto shaft in increments,
stopping to check clearance between impeller
and bearing body.
d.
Use a thickness gage to ensure clearance of
0.027 to 0.035 in. (0,69 to 0,89 mm) is
maintained between impeller (3) blades and
bearing body (2).
NOTE
FOLLOW-ON-TASK:
Install water pump per TM 5-3895-373-20.
END OF TASK
2-324