TM 5-3895-373-34
2.77
REPLACE/REPAIR SCREED VIBRATION FLOW DIVIDER.
A.
REMOVE - Continued.
3.
REMOVE SCREED VIBRATION FLOW DIVIDER
FROM SCREED.
Hydraulic
oil
can
be
moderately
flammable and can be an irritant to
the
skin,
eyes,
and
respiratory
system. Avoid prolonged exposure.
Eye protection and rubber gloves
must be worn when working with
hydraulic oil.
a.
Place machinery wiping towel below hydraulic
fittings to absorb any hydraulic oil that may
leak from hoses when removed. Discard used
machinery wiping towels in accordance with
local procedures.
b.
Disconnect hoses (6) and tube (7) from elbows
(5). Cap off elbows, plug hose, and tube with
protective caps.
c.
Remove bolts (8) and lockwashers (9) from
screed vibration flow divider (4). Discard
lockwashers.
d.
Remove screed vibration flow divider (4) from
mounting bracket (10) in screed.
e.
Drain hydraulic oil from screed vibration flow
divider (4) into a drain pan. Dispose of
hydraulic
oil
in
accordance
with
local
procedures.
GO TO NEXT PAGE
2-1086