TM 5-3895-373-34
A.
REMOVE - Continued.
2.
CLEAN SCREED VIBRATION FLOW DIVIDER
AND ELBOWS.
Cleaning solvent, P-D-680, is TOXIC
and flammable. Wear protective
goggles and gloves.
Use only in a well ventilated area.
Avoid contact with skin, eyes, and
clothes, and do not breathe vapors.
Keep away from heat or flame. Never
smoke
when
using
solvent;
the
flashpoint
for
Type
m
cleaning
solvent is 200°F (93,3°C).
Failure to do so may result in injury
or death to personnel.
If personnel become dizzy while
using cleaning solvent, immediately
get fresh air and medical help. If
solvent contacts skin or clothes,
flush with cold water. If solvent
contacts eyes, flush eyes with water
and get immediate medical attention.
a.
Wipe exterior of screed vibration flow
divider (4) with a cleaning cloth soaked
in cleaning solvent to remove grease
and dirt.
b.
Clean elbows (5) to remove any grease and
dirt.
GO TO NEXT PAGE
2-1085