TM 5-3895-373-34
B.
CLEAN.
1.
CLEAN ALL METAL PARTS.
Cleaning solvent, P-D-680, is TOXIC
and flammable. Wear protective
goggles and gloves. Use only in a
well ventilated area. Avoid contact
with skin, eyes, and clothes, and do
not breathe vapors. Keep away from
heat or flame. Never smoke when
using solvent; the flashpoint for Type
m cleaning solvent is 200°F (93,
30C). Failure to do so may result in
injury or death to personnel.
If personnel become dizzy while
using cleaning solvent, immediately
get fresh air and medical help. If
solvent contacts skin or clothes,
flush with cold water. If solvent
contacts eyes, flush eyes with water
and get immediate medical attention.
a.
Clean all metal parts except bearings in cleaning
solvent. Remove hard deposits with a cleaning
brush.
b.
Wipe bearings off with a lint-free cloth.
Compressed air used for cleaning
purposes will not exceed 30 psi (207
kPa). Use only with effective chip
guarding and personal protective
equipment (goggles/face shield and
gloves). Failure to take proper
precautions may result in severe
injury or loss of vision.
c.
Use 30 psi (207 kPa) maximum compressed air
to blow any foreign material from grooves,
threaded surfaces, and holes. Do not use
compressed air on bearings.
GO TO NEXT PAGE
2-1061