TM 5-3895-373-34
D.
INSPECT - Continued.
2.
INSPECT VALVE HOUSING.
a.
Inspect valve housing (64) seal groove C for
contamination, foreign material, nicks, burrs,
sharpened, or broken edges.
b.
Replace valve housing (64) if nicks, burrs,
sharpened, or broken edges cannot be removed
with emery cloth.
Cleaning solvent, P-D-680, is TOXIC
and flammable. Wear protective
goggles and gloves. Use only in a
well ventilated area. Avoid contact
with skin, eyes, and clothes, and do
not breathe vapors. Keep away from
heat or flame. Never smoke when
using solvent; the flashpoint for Type
Im cleaning solvent is 200°F (93,3°C).
Failure to do so may result in injury
or death to personnel.
If personnel become dizzy while
using cleaning solvent, immediately
get fresh air and medical help. If
solvent contacts skin or clothes,
flush with cold water. If solvent
contacts eyes, flush eyes with water
and get immediate medical attention.
c.
Rinse contamination and foreign matter from
valve housing passages with cleaning solvent.
3.
INSPECT VALVE AND VALVE PLATE.
a.
Inspect valve (75) internal gear, splines D, for
sharpened, chipped, or broken gear splines.
Replace valve if gear splines are damaged.
b.
Inspect valve plate (76) for
nicks,
burrs,
sharpened or broken edges. Replace valve
plate if damage cannot be removed with emery
cloth.
GO TO NEXT PAGE
2-985