TM 5-3895-373-20D. ASSEMBLE Continued.i.Install lockwasher (50) and flat washer (51) ontohex head cap screw (49).Sealing compound can cause eyedamage. Wear safety goggles/glasseswhen using. Avoid contact with eyes. Ifcompound contacts eyes, flush eyeswith water and get immediate medicalattention.j.Apply sealing compound to threads of hex headcap screw (49).k.Install vent cover plate (52) and secure with flatwasher (51), lockwasher (50), and hex head capscrew (49). Tighten cap screw to 9 lb-ft (12N•m).Anti-seize compound can cause eyedamage. Wear safety goggles/glasseswhen using. Avoid contact with eyes. Ifcompound contacts eyes, flush eyeswith water and get immediate medicalattention.1. Apply anti-seize compound to threads of glowplug (47).m. Install gasket (48) and glow plug (47). Tightenglow plug to 33 Ib-ft (45 N•m).GO TO NEXT PAGE14-41