TM 5-3895-373-2014.5. REPLACE BURNER CHAMBER AND FUEL SPRAY NOZZLE - Continued.E.INSTALL Continued.h.Install flat washers (24) onto bolts (25).Sealing compound can cause eyedamage. Wear safety goggles/glasseswhen using. Avoid contact with eyes.If compound contacts eyes, flusheyes with water and get immediatemedical attention.i.Apply sealing compound to threads of bolts (25).j.Install insulation (27 and 28) onto shield (14).Place shield (26) over the insulation and securewith bolts (25), lockwashers (23), and hex nuts(22). Tighten hex nuts to 19 lb-ft (26 N•m).k.Apply sealing compound to threads of bolts (13).l. Install shield (14) and secure with bolts (13), flatwashers (12), lockwashers (11), and hex nuts(10). Tighten hex nuts to 19 lb-ft (26 N•m).GO TO NEXT PAGE14-46